Check the chemistry
Quachem Workbench marks every chemistry default as provisional until a chemist has reviewed it. This page lists each default that version 0.1.0 uses, from the default method to the reference data of the validation suite. For each one you can read its current value, the source the project recorded and one question for a chemist.
You do not need to review every item. The project put the items most likely to change a computed result first in each group, so the first few items in a group you know well are the most useful to check.
How to send feedback
Section titled “How to send feedback”Each item ends with a link to a chemistry review issue on GitHub, with the item already filled in. Write the value you would choose, or “agree” if the current value is fine, and add a reference where you can, because the project records the reviewer’s source next to each value it keeps. You need a GitHub account to open an issue. You can give your field, and you do not need to give your name.
To answer many items at once, download the review packet, type your answers after each Answer: line, and paste the answered items into one chemistry review issue.
How each item is laid out
Section titled “How each item is laid out”Each item gives the same five facts. “Now” is what the workbench does today, with the exact value. “Set in” is the file and line that sets it. “Source recorded” is what the project cites, or “no source recorded” when it cites none; a citation that the project took from memory or could not read is marked as such. “Why it matters” says how the value changes a result. “Question” is what the project needs from you. Line numbers refer to the repository on the main branch when this packet was written, so a line may have moved since.
Two scope notes apply throughout. The validation suite is built (src/qchem_workbench/validation), and its smoke profile has run end to end (docs/evidence/2026-11-24-validation-smoke), but the project has not yet made a full run, so the items in group E describe the suite’s data and settings without results. Interface display colours, remote-job polling intervals, PubChem request throttling and archive size limits are also marked provisional in the code. They are technical choices without chemical content, and this packet leaves them out.
A. Methods and basis sets
Section titled “A. Methods and basis sets”A1. Default method: r2SCAN-3c
Section titled “A1. Default method: r2SCAN-3c”- Now: a job that names no method runs r2SCAN-3c, with its basis fixed at def2-mTZVPP and its Coulomb term fitted (RI-J) with def2-mTZVPP-RIJ. The resolver marks the method choice provisional and marks the basis and the density fitting as part of the method’s definition. The method runs on the CPU only, because GPU4PySCF 1.9.2 raises “Only wb97x-3c is supported” for it. The GPU gradient in GPU4PySCF 1.9.2 also has no gCP term, so the project plans to check that term before it enables r2SCAN-3c on the GPU.
- Set in:
src/qchem_workbench/core/defaults.py:15;src/qchem_workbench/core/methods.py:50-73;src/qchem_workbench/runner/engine.py:68-86(the PySCFdft3csetup) and:106-111(density fitting). - Source recorded: Grimme, Hansen, Ehlert and Mewes, J. Chem. Phys. 2021, 154, 064103, and the spec’s chemistry defaults table (
docs/spec.md:210). The project could not read the paper’s full text (see A4), so the description of r2SCAN-3c as “designed for accurate geometries and energies at low cost” is the spec’s own summary. - Why it matters: this method produces the energies, geometries, frequencies and spectra of every job that keeps the default.
- Question: Is r2SCAN-3c the right default for optimisations and frequencies of closed-shell organic molecules for experimental chemists, and does the combination the workbench builds (r2SCAN, D4, gCP, def2-mTZVPP, RI-J) match the published definition?
- Answer item A1 in a chemistry review issue
A2. Default basis set for methods without a fixed basis: def2-TZVP
Section titled “A2. Default basis set for methods without a fixed basis: def2-TZVP”- Now: B3LYP-D3(BJ), PBE0-D3(BJ), ωB97X-V and Hartree-Fock default to def2-TZVP. A researcher can name any basis set that PySCF or basis-set-exchange accepts. The workbench uses def2-SVP only as the basis of its CPU-against-GPU agreement tests, and it does not use def2-SVP as a default anywhere.
- Set in:
src/qchem_workbench/core/defaults.py:17;src/qchem_workbench/core/methods.py:77,:102,:147and:173. - Source recorded: the spec’s chemistry defaults table (
docs/spec.md:211), which lists each of these methods with def2-TZVP. No literature source is recorded for choosing the triple-zeta level. - Why it matters: the basis set sets the cost and the accuracy of every non-composite calculation, and DFT geometries and frequencies shift with it.
- Question: Is def2-TZVP the right default for these four methods, in particular for B3LYP-D3(BJ) optimisations and frequencies and for Hartree-Fock? Should a smaller option such as def2-SVP be offered as a quick choice, or a larger one for single-point energies?
- Answer item A2 in a chemistry review issue
A3. Coulomb and exchange treatment: no density fitting for most methods
Section titled “A3. Coulomb and exchange treatment: no density fitting for most methods”- Now: B3LYP-D3(BJ), PBE0-D3(BJ), ωB97X-V, Hartree-Fock and ωB97X-3c compute Coulomb and exchange exactly, with no density fitting. Only r2SCAN-3c uses density fitting, as its definition requires. The resolver marks the choice provisional for the first five.
- Set in:
src/qchem_workbench/core/methods.py:76-81,:101-106,:123-128,:146-150and:172-176(thedensity_fittingfields and their sources);src/qchem_workbench/runner/engine.py:106-111. - Source recorded: “Workbench choice: exact Coulomb and exchange for non-composite methods; provisional”. For ωB97X-3c the recorded reason is that PySCF has no dedicated auxiliary basis for vDZP (
pyscf/dft/dft3c.py). No literature source is recorded. - Why it matters: exact integrals remove fitting error from the energies and cost more time and memory, which limits the molecule size on an 8 GB GPU.
- Question: Is exact Coulomb and exchange the right choice for these methods and for the molecule sizes the workbench targets (about 50 atoms), or should RI-J or RIJK fitting with def2/J or def2/JK auxiliary basis sets be the default for the hybrids? Does the published ωB97X-3c definition assume exact integrals?
- Answer item A3 in a chemistry review issue
A4. r2SCAN-3c effective core potentials (the def2 ECP)
Section titled “A4. r2SCAN-3c effective core potentials (the def2 ECP)”- Now: PySCF’s
dft3csetup gives r2SCAN-3c no effective core potential. The runner then assigns the def2 ECP to every element that has one in the def2 family (Rb to Rn), on the CPU. basis-set-exchange holds no ECP record under def2-mTZVPP, so the runner names the potentialdef2-tzvpp; the project notes that all def2 sets share one ECP. A test with HI gives 26 electrons and -298.33057570 hartree. The methods paragraph states the assignment, for example “The def2 effective core potentials replaced the core electrons of I (Peterson et al., 2003).” - Set in:
src/qchem_workbench/runner/ecp.py:17(METHOD_ECP) and:162-175(assignment);src/qchem_workbench/runner/engine.py:59-65;docs/decisions.md:336. - Source recorded: the r2SCAN-3c paper (Grimme, Hansen, Ehlert and Mewes, J. Chem. Phys. 2021, 154, 064103) is behind a paywall and the project could not read it. The project relies instead on Gasevic, Stückrath, Grimme and Bursch, J. Phys. Chem. A 2022, 126, 3826, which says that “the original GTO-based r2SCAN-3c is based on a modified Ahlrichs basis set that is constructed for default use with ECPs”. That text does not name the ECP. Choosing the def2 ECP is an inference from the Ahlrichs basis, recorded as provisional until a chemist checks it.
- Why it matters: for any molecule containing an element from Rb onward (iodine, for example), the energy is meaningless without a core potential, and a different ECP gives different results.
- Question: Does r2SCAN-3c use the def2 ECP for Rb to Rn, as the paper and its supporting information state? If it uses another potential, which one?
- Answer item A4 in a chemistry review issue
A5. r2SCAN-3c Coulomb-fitting fallback (def2-universal-jfit)
Section titled “A5. r2SCAN-3c Coulomb-fitting fallback (def2-universal-jfit)”- Now: r2SCAN-3c fits its Coulomb term with def2-mTZVPP-RIJ. basis-set-exchange 0.12 defines that auxiliary basis only for H to Ar and Fe (19 elements), and PySCF stops with a
BasisNotFoundErrorfor any other element. For a molecule containing such an element, the runner gives that element def2-universal-jfit and keeps def2-mTZVPP-RIJ for the others. Molecules made only of H to Ar and Fe are unchanged. A test with HBr gives -2574.73599295 hartree. - Set in:
src/qchem_workbench/runner/ecp.py:187-203(r2scan_3c_auxbasis);src/qchem_workbench/runner/engine.py:106-111;docs/decisions.md:336. - Source recorded: Weigend, Phys. Chem. Chem. Phys. 2006, 8, 1057 for def2-universal-jfit as the def2/J fitting basis. The choice of that basis for r2SCAN-3c is recorded as “a workbench decision, provisional until the chemist reviews it”.
- Why it matters: bromine, iodine and every other element outside the covered 19 would otherwise fail at the first SCF, and the fitting basis changes their energies by the fitting error.
- Question: Is def2-universal-jfit an acceptable Coulomb-fitting basis for r2SCAN-3c with the def2-mTZVPP orbital basis for these elements, or should the workbench refuse r2SCAN-3c for them and suggest another method?
- Answer item A5 in a chemistry review issue
A6. Effective core potentials for all other methods (ecp = basis-defined)
Section titled “A6. Effective core potentials for all other methods (ecp = basis-defined)”- Now: for a method with a free basis choice, an element receives an ECP when the basis set’s own definition gives it one. The runner reads that definition from basis-set-exchange (PySCF’s
bse_predefined_ecp) and from PySCF’s own files. A third rule treats a basis with fewer contracted s functions than the element’s occupied s shells as an ECP valence basis, and the job is refused when no ECP is known for that pair (for example minao for In to Xe, and def2-mTZVP and def2-mTZVPP for Cs). ωB97X-3c keeps the vDZP ECPs that PySCF’sdft3cassigns per element. Elements without a defined ECP stay all-electron. The result’s provenance records the element-to-ECP map. - Set in:
src/qchem_workbench/core/defaults.py:19;src/qchem_workbench/runner/ecp.py:76-117(the three rules);docs/decisions.md:332-340. - Source recorded: basis-set-exchange 0.12 and PySCF 2.15.1 behaviour, “for the chemist’s review”. The decision record states that “nothing here has had a chemist’s review of which basis and element pairs should use an ECP”. For minao the project could not determine which ECP matches, so it refuses the basis.
- Why it matters: a missing ECP with a valence-only basis gives a meaningless energy with no error message (HI in def2-SVP gave 54 electrons and -298.39 hartree before the fix), so each assignment decides whether a heavy-element result is usable.
- Question: Is “use the ECP that the basis set’s own definition names” the right rule, and is the s-shell-count rule a sound way to detect valence-only bases? Are there basis and element pairs for which the workbench should refuse the job or choose another ECP?
- Answer item A6 in a chemistry review issue
A7. B3LYP-D3(BJ): functional variant and dispersion
Section titled “A7. B3LYP-D3(BJ): functional variant and dispersion”- Now: the method uses PySCF’s
b3lyp-d3bj. The engine probe showed that PySCF’sb3lypresolves to Libxc functional 402 (HYB_GGA_XC_B3LYP, the VWN-RPA variant, identical to PySCF’sb3lypg). The provenance names the variant. The method adds D3 dispersion with Becke-Johnson damping. - Set in:
src/qchem_workbench/core/methods.py:76-96;docs/spec.md:217. - Source recorded: PySCF documentation and the engine probe of 2026-11-23 (
docs/evidence/2026-11-23-engine-probe); citations for B3LYP, LYP, Libxc, D3 and BJ incore/citations.py. The spec also says thatb3lyp5(VWN5) “is available for reproducing results from codes that use it”, butcore/methods.pyhas no entry that offers it, so the spec and the code disagree on this point. - Why it matters: the VWN-RPA and VWN5 variants give slightly different energies, so a comparison with published B3LYP numbers depends on the variant. The project did not record which D3(BJ) parameters the dispersion library applies to B3LYP.
- Question: Is the VWN-RPA variant acceptable as the workbench’s “B3LYP”, and should VWN5 be offered as a separate choice (the spec says it should)? Are the D3(BJ) parameters PySCF applies to B3LYP the published ones?
- Answer item A7 in a chemistry review issue
A8. ωB97X-3c: vDZP basis, ECPs and exact integrals
Section titled “A8. ωB97X-3c: vDZP basis, ECPs and exact integrals”- Now: the basis is fixed at vDZP (
grimme vdzp), with the effective core potentials that PySCF’sdft3cassigns per element. Coulomb and exchange are exact. The method runs on both the CPU and the GPU. CPU and GPU agree to 9e-13 hartree in energy, 4e-7 hartree/bohr in gradient and 0.2 cm⁻¹ in frequencies on water. On the GPU, the analytic IR tensors differ from GPU finite differences by 6.1e-5 atomic units; the cause inside GPU4PySCF is undiagnosed. - Set in:
src/qchem_workbench/core/methods.py:123-139;docs/decisions.md:141-156and:215. - Source recorded: Müller, Hansen and Grimme, J. Chem. Phys. 2023, 158, 014103. The project lead approved the method on 2026-11-23, which predates any chemist’s review.
- Why it matters: this is the only range-separated hybrid on offer that runs without a GPU restriction, so it is the fallback the interface suggests when a method needs a GPU that is missing.
- Question: Is the workbench’s ωB97X-3c (the ωB97X-V functional without VV10, D4 dispersion, the vDZP basis and its ECPs, exact integrals) consistent with the published method, and is it appropriate as the range-separated hybrid option for organic molecules?
- Answer item A8 in a chemistry review issue
A9. Other offered methods: PBE0-D3(BJ), ωB97X-V and Hartree-Fock
Section titled “A9. Other offered methods: PBE0-D3(BJ), ωB97X-V and Hartree-Fock”- Now: PBE0-D3(BJ)/def2-TZVP, ωB97X-V/def2-TZVP and HF/def2-TZVP are offered. ωB97X-V optimisations and frequencies need an NVIDIA GPU, because PySCF 2.15.1 has no CPU gradient for it; single points run on either device. The workbench sets one grid level for the whole calculation and adds no separate setting for the VV10 nonlocal term, so PySCF’s own default applies to it.
- Set in:
src/qchem_workbench/core/methods.py:101-121,:146-170and:172-190;docs/spec.md:211. - Source recorded: ωB97X-V, Mardirossian and Head-Gordon, Phys. Chem. Chem. Phys. 2014, 16, 9904, added at the project lead’s request. PBE0 and B3LYP are “benchmarked in GMTKN55 and covered by published frequency scale factors” (
docs/spec.md:211). Najibi and Goerigk, J. Chem. Theory Comput. 2018, 14, 5725 backs the ωB97X-V note, but the project could not read its full text (see A10). - Why it matters: the option list decides which levels of theory a researcher can choose, and the VV10 grid affects ωB97X-V energies.
- Question: Is this the right set of methods to offer for closed-shell organics? Is anything missing that you would expect (for example a double-hybrid, MP2 or a meta-GGA hybrid), or anything here that you would remove? Is PySCF’s default VV10 grid adequate for ωB97X-V?
- Answer item A9 in a chemistry review issue
A10. Method caveat notes and generated methods-paragraph wording
Section titled “A10. Method caveat notes and generated methods-paragraph wording”- Now: each method carries a plain-language note that the interface and
qcw methodsshow wherever a researcher chooses a method, and a template for the generated methods paragraph. The notes read as follows. - r2SCAN-3c: “This is the default, a fast all-round method for geometries, frequencies and energies. It runs on the CPU only for now, because the released GPU engine does not support it yet.”
- B3LYP-D3(BJ): “This is the most widely used hybrid, and it is useful for comparison with published work. The workbench uses the Libxc definition with VWN-RPA correlation; some programs use VWN5 instead, which gives slightly different energies.”
- PBE0-D3(BJ): “This widely used hybrid has no empirical fitting in the functional itself, which makes it a useful second opinion beside B3LYP-D3(BJ).”
- ωB97X-3c: “This range-separated hybrid runs on both the CPU and the GPU. It uses a compact basis set designed for it, which keeps it cheap. It is newer than the other options, so fewer published benchmarks use it.”
- ωB97X-V: “Its developers, and an independent assessment on the GMTKN55 benchmark (Najibi and Goerigk, 2018), found it accurate and robust. Optimisations and frequencies need an NVIDIA GPU, because the CPU engine has no gradients for it, while single-point energies also run on the CPU. Without a GPU, choose ωB97X-3c.”
- Hartree-Fock: “Hartree-Fock includes no electron correlation, so its energies and frequencies are less accurate than the other options. It is mainly useful for teaching and for checking results.”
- Set in:
src/qchem_workbench/core/methods.py:64,:93,:117,:139,:160and:187(notes);:58,:88,:113,:132,:154and:183(methods-paragraph templates). - Source recorded: for the ωB97X-V note, the paper’s abstract and the authors’ follow-up paper (
docs/decisions.md:182-186). The first wording (“ranks among the most accurate on the GMTKN55 benchmark”) was withdrawn because the abstract did not support it, and the project read only the abstract of the 2018 paper because the full text is paywalled. No source is recorded for the other five notes or for the methods-paragraph templates. - Why it matters: researchers choose a method from these notes and copy the paragraph into papers.
- Question: Is each note accurate and fair? Does each methods-paragraph template describe its method correctly and cite the right works?
- Answer item A10 in a chemistry review issue
A11. Scope of version 1: closed-shell, gas phase, and excluded elements
Section titled “A11. Scope of version 1: closed-shell, gas phase, and excluded elements”- Now: the workbench accepts only singlet molecules with an even electron count. It excludes the d-block elements of groups 3 to 12 (Sc to Zn, Y to Cd, and Hf to Hg together with La to Lu), so it rejects zinc, cadmium and mercury along with the transition metals. Every result is a gas-phase value and the interface labels it as such. Solvent models are planned for version 1.1.
- Set in:
src/qchem_workbench/core/molecule.py:26-36(the rules);src/qchem_workbench/core/elements.py:11-15(the excluded elements). - Source recorded: spec section 5 (
docs/spec.md:234-238) and an open question (docs/spec.md:399) that asks whether Zn, Cd and Hg should be accepted. The exclusion is recorded as a scope decision with no chemical source. - Why it matters: the rules decide which molecules a researcher can run at all, and the restricted closed-shell treatment is wrong for some species that pass the electron-count check.
- Question: Should version 1 accept Zn, Cd and Hg, and with which methods and basis sets (the def2 sets use ECPs for Cd and Hg)? Is the gas-phase label sufficient for tautomer and isomer rankings, where solvent can change the order?
- Answer item A11 in a chemistry review issue
B. Numerical settings
Section titled “B. Numerical settings”B1. DFT integration grid for r2SCAN-3c frequency jobs: level 5
Section titled “B1. DFT integration grid for r2SCAN-3c frequency jobs: level 5”- Now: r2SCAN-3c frequency and opt+freq jobs run the whole job on PySCF grid level 5. Single points and plain optimisations use level 3. A
grid_levelin the job input always wins, and the methods paragraph reports the level used. On the water fixture on the CPU, a frequency job took 24.9 s at level 3 and 47.9 s at level 5, and an opt+freq job took 37.7 s and 72.6 s. The analytic atomic polar tensors differ from finite differences by 2.2e-3 au at level 3 and 8.6e-4 au at level 5. - Set in:
src/qchem_workbench/core/methods.py:69-73;src/qchem_workbench/core/calculation.py:126-131;docs/decisions.md:214;docs/spec.md:213. - Source recorded: PySCF 2.15.1 (
pyscf/hessian/rks.py,_check_mgga_grids) warns “MGGA Hessian is sensitive to dft grids. grids.level {grids.level} may not be dense enough.” when a meta-GGA Hessian runs below level 5. The level itself is a decision of the project lead on 2026-11-23, “provisional until the chemist collaborator reviews it”. - Why it matters: the grid changes the frequencies (water: 1636.55, 3869.16 and 3990.46 cm⁻¹ at level 3, and 1638.14, 3869.50 and 3991.22 cm⁻¹ at level 5) and the IR intensities. A structure optimised at level 3 and analysed at level 5 meets a slightly different surface, which the stationary-point check (B5) reports.
- Question: Is level 5 the right grid for r2SCAN-3c Hessians? Should the optimisation also run at level 5 so that both steps use the same surface, or is a level above 5 warranted?
- Answer item B1 in a chemistry review issue
B2. DFT integration grid for everything else: level 3
Section titled “B2. DFT integration grid for everything else: level 3”- Now: every other DFT task and method uses PySCF grid level 3. That covers B3LYP-D3(BJ), PBE0-D3(BJ), ωB97X-V and ωB97X-3c (including their frequency jobs), and r2SCAN-3c single points and optimisations. The workbench sets no separate grid for the VV10 term of ωB97X-V.
- Set in:
src/qchem_workbench/core/defaults.py:28;src/qchem_workbench/runner/engine.py:114-115;docs/spec.md:213. - Source recorded: “PySCF 2.15.1 default (
dft.gen_grid.Grids.level)”. The project records no chemistry source for level 3 being adequate. For the GGA hybrids it measured IR tensor gaps of 2e-6 au (B3LYP-D3(BJ)/def2-SVP) and 1.8e-5 au (ωB97X-3c) against finite differences on water. - Why it matters: grid error enters energies, geometries and frequencies, and it matters most for meta-GGAs and for ωB97X-V’s nonlocal term.
- Question: Is level 3 adequate for DFT optimisations and relative energies of the target molecules, or should the default be finer for some or all methods?
- Answer item B2 in a chemistry review issue
B3. SCF convergence settings
Section titled “B3. SCF convergence settings”- Now: the SCF energy convergence threshold is 1e-9 hartree and the SCF stops with a “did not converge” failure after 100 cycles. The workbench sets no gradient threshold of its own, so PySCF’s default applies (the square root of the energy threshold, 3e-6 here). It runs a restricted (closed-shell) SCF and performs no stability analysis of the solution.
- Set in:
src/qchem_workbench/core/defaults.py:25-26;src/qchem_workbench/runner/engine.py:112-113and:119-131. - Source recorded: the threshold is “PySCF 2.15.1 default (
scf.hf.SCF.conv_tol)”. The 100-cycle limit is a workbench choice (PySCF allows 50) with no further source. No source is recorded for omitting a stability check. - Why it matters: a looser threshold leaves noise in gradients and Hessians, and an unconverged or unstable restricted solution gives a wrong energy with no warning.
- Question: Are 1e-9 hartree and 100 cycles appropriate? Should the workbench test the restricted solution for an instability to an unrestricted one, and what should it do when it finds one?
- Answer item B3 in a chemistry review issue
B4. Geometry optimiser and its convergence criteria
Section titled “B4. Geometry optimiser and its convergence criteria”- Now: geomeTRIC 1.1.1 optimises the geometry in at most 100 steps. The criteria are energy 1e-6 hartree, RMS gradient 3e-4 hartree/bohr, maximum gradient 4.5e-4 hartree/bohr, RMS displacement 1.2e-3 bohr and maximum displacement 1.8e-3 bohr. Every SCF along the path must converge, or the job fails.
- Set in:
src/qchem_workbench/core/defaults.py:30-37;src/qchem_workbench/runner/optimise.py:8-16;docs/spec.md:400. - Source recorded: geomeTRIC 1.1.1 as a required dependency of GPU4PySCF, and “PySCF 2.15.1 (
geomopt.geometric_solver.kerneldocstring; geomeTRIC defaults)” for the criteria. The choice between geomeTRIC and pyberny is an open question that the spec assigns to the chemist (docs/spec.md:400). - Why it matters: looser criteria leave residual gradients that the stationary-point check (B5) can flag, and the optimiser’s robustness determines how often jobs fail on floppy molecules.
- Question: Are these criteria tight enough for a geometry that feeds a frequency calculation, and is 100 steps enough? Which optimiser converges more reliably on organic molecules, geomeTRIC or pyberny?
- Answer item B4 in a chemistry review issue
B5. Stationary-point check and the definition of a minimum
Section titled “B5. Stationary-point check and the definition of a minimum”- Now: every frequency job computes the nuclear gradient at the Hessian’s geometry (per-atom RMS and maximum norms, without grid response). If the RMS is not strictly below 3e-4 hartree/bohr or the maximum is not strictly below 4.5e-4 hartree/bohr, the result carries a warning, is not marked a minimum, and has no thermochemistry. Any negative frequency, with no tolerance, also makes the result “not a minimum” and removes the thermochemistry. The warning leaves the frequencies and intensities in the result. Measured on water: an unoptimised structure gave RMS 4.4e-3 and was flagged; a level-3 optimum analysed at level 5 gave 2.9e-5 and was not flagged.
- Set in:
src/qchem_workbench/core/result.py:86-89(the thresholds test) and:135-141(is_minimum);src/qchem_workbench/runner/frequencies.py:150-176and:255-272;docs/decisions.md:225-259;docs/spec.md:214. - Source recorded: the project lead’s decisions of 2026-11-23, “provisional until the chemist collaborator reviews it”: a warning in place of a failure, and thermochemistry only for a minimum. The per-atom norms follow geomeTRIC 1.1.1 (
OptObject.calcGradNorm). No source is recorded for using the optimiser’s thresholds as the stationary-point test, and none for a zero tolerance on imaginary frequencies. - Why it matters: it decides when a researcher receives Gibbs energies. A small imaginary frequency from a soft mode or from grid noise withholds all thermochemistry from an otherwise good result.
- Question: Should small imaginary frequencies (for example below a few tens of cm⁻¹) be tolerated, flagged or treated as real? Are the optimiser’s gradient thresholds the right test for “stationary”, especially for floppy molecules, where the project measured only water? Is withholding thermochemistry the right response, or should it be reported with a warning?
- Answer item B5 in a chemistry review issue
B6. Symmetry tolerance for the point group and symmetry number: 0.01 bohr
Section titled “B6. Symmetry tolerance for the point group and symmetry number: 0.01 bohr”- Now: the runner finds every symmetry operation that maps the structure onto itself within 0.01 bohr (5.29e-3 Å), symmetrises the structure, names its point group with PySCF and counts the proper rotations as the rotational symmetry number σ. The RRHO entropy and Gibbs energy use that σ. A distortion smaller than about the tolerance counts as symmetric (methane with one C-H bond 0.005 Å longer is treated as Td, σ = 12), and one of 0.01 Å or more does not. The tolerance can be set per job as
symmetry_tolerance_bohr. When σ cannot be found (for example a nearly linear structure), the result keeps its frequencies and has no thermochemistry. - Set in:
src/qchem_workbench/core/defaults.py:42-46;src/qchem_workbench/runner/symmetry.py:1-12(whose docstring names aSYMMETRY_TOLERANCE_ANGSTROMconstant that does not exist; the setting issymmetry_tolerance_bohr);docs/decisions.md:261-288;docs/spec.md:215. - Source recorded: NWChem’s default atom-equivalence threshold for automatic symmetry detection (
autosym, default 1d-2 in atomic units,threquivinsrc/geom/geom_input.F), read from the NWChem source on 2026-11-23. The decision record rejects other documented defaults as too loose or not a single distance. PySCF’s own detection uses 1e-5 bohr, which loses σ for a structure with file rounding noise and shifts G by RT ln σ (1.47 kcal/mol for methane). - Why it matters: σ changes entropy and Gibbs energy by RT ln σ, and a researcher comparing isomers or conformers sees that directly.
- Question: Is 0.01 bohr the right tolerance, and is treating near-symmetric structures as symmetric acceptable for flexible molecules? Is the number of proper rotations of the point group the right σ here, with no further correction for internal rotors or chirality?
- Answer item B6 in a chemistry review issue
C. Structure building in the 3D editor and structure preparation
Section titled “C. Structure building in the 3D editor and structure preparation”C1. Fragment geometries compared with Allen 1987
Section titled “C1. Fragment geometries compared with Allen 1987”- Now: the
fragmentcommand attaches one of seven groups, each with an idealised geometry. The table gives each group’s bond lengths (Å) and angles, computed from the stored coordinates. - Methyl: C-H 1.09; H-C-H and X-C-H 109.5°.
- Trifluoromethyl: C-F 1.35; F-C-F and X-C-F 109.5°.
- Hydroxyl: O-H 0.96; X-O-H 108.5°.
- Amino: N-H 1.01; H-N-H and X-N-H 109.5° (a pyramid).
- Phenyl: aromatic C-C 1.39; aromatic C-H 1.08; every ring angle and the X-C-C angles 120.0°; bonds alternate single and double (Kekulé form).
- Carboxylic acid: C=O 1.21; C-O 1.34; O-H 0.97; O=C-O 120.0°; C-O-H 120.0°; X-C-O 120.0°.
- Nitrile: C≡N 1.16; X-C≡N 180.0°.
- Set in:
src/qchem_workbench/editor/fragments.py:29-51;docs/decisions.md:838-840. - Source recorded: the values are “this project’s own idealisations”, rounded typical values for each bond type, taken from no program’s templates and not copied from any table. The record names a published table of average bond lengths as the place to check them, Allen et al., J. Chem. Soc., Perkin Trans. 2, 1987, S1-S19, and states that the values “have not yet been compared with it, which is the chemist’s review”. The project has not read that table for this purpose.
- Why it matters: the fragment is the starting geometry for a clean-up and then a quantum-chemical optimisation, so a poor value costs optimiser steps and can bias the conformer the optimiser finds.
- Question: Please compare each value in the list with Allen et al. 1987 and mark any that are off. In particular, are a 120° C-O-H angle in the carboxylic acid and tetrahedral geometry at the amino nitrogen reasonable starting points?
- Answer item C1 in a chemistry review issue
C2. Placement of new atoms and attached groups: bond length and angle
Section titled “C2. Placement of new atoms and attached groups: bond length and angle”- Now:
add <element>, <atom>places a new atom at the sum of the two covalent radii from its anchor, pointing away from the anchor’s other bonds. With one existing bond it uses the tetrahedral angle (109.4712206°) in the plane that puts the new atom trans to a second neighbour, so chains zigzag; with no bond it goes along +x; with several bonds it points opposite their sum.fragmentuses the same radius-sum rule for the new bond to the attached group, whatever the bond order or hybridisation. An element with no radius entry falls back to 0.75 Å. - Set in:
src/qchem_workbench/editor/edits.py:70-95(bonded_position) and:11(TETRAHEDRAL);src/qchem_workbench/editor/fragments.py:64-96;docs/decisions.md:715-717. - Source recorded: the sum of covalent radii (see C3) and the ideal sp3 angle of valence-shell electron-pair repulsion theory. The record states that “the rule is this project’s own and no program’s code was used”, and marks it provisional.
- Why it matters: the placement sets the starting bond lengths and angles for every drawn or attached atom, including sp2 and sp carbons that receive the sp3 angle and a single-bond radius sum.
- Question: Is the radius-sum bond length with a tetrahedral angle an acceptable starting rule for the clean-up, or should the new bond length and angle depend on the element’s hybridisation or on the bond order the researcher draws?
- Answer item C2 in a chemistry review issue
C3. Covalent radii and the 0.75 Å fallback
Section titled “C3. Covalent radii and the 0.75 Å fallback”- Now: the editor holds one covalent radius per element, H to Rn (for example H 0.32, C 0.75, N 0.71, O 0.63 and Br 1.14 Å), used for bond perception (C4) and for placing atoms (C2). The radii are the single-bond radii of Pyykkö and Atsumi, taken from the Blue Obelisk Data Repository.
- Set in:
src/qchem_workbench/editor/elements.py:11-37;src/qchem_workbench/editor/edits.py:77;src/qchem_workbench/editor/fragments.py:77-78. - Source recorded: Pyykkö and Atsumi, Chem. Eur. J. 2009, 15, 186 (single-bond radii), through the Blue Obelisk Data Repository
elements.xmlat commitabff999b6bc6a893252eed7df0fae52ddfeed9dd(docs/decisions.md:692). The project copied the values from the repository and has not checked them against the paper. The 0.75 Å fallback has no source recorded. - Why it matters: every perceived bond and every placed atom depends on these radii.
- Question: Are single-bond radii the right basis for both perceiving bonds and placing atoms? Please spot-check the radii for the elements you use most.
- Answer item C3 in a chemistry review issue
C4. Bond perception: 0.45 Å tolerance and 0.4 Å minimum
Section titled “C4. Bond perception: 0.45 Å tolerance and 0.4 Å minimum”- Now: a single bond joins two atoms that are farther apart than 0.4 Å and closer than the sum of their covalent radii plus 0.45 Å. The rule creates only single bonds; the researcher changes orders by hand. It has no valence-based pruning, so overlapping atoms can show extra bonds until the researcher fixes them.
- Set in:
src/qchem_workbench/editor/structure.py:23-26(BOND_TOLERANCE_ANGSTROMandMIN_BOND_ANGSTROM) and:174(perceive_bonds);docs/decisions.md:711-713. - Source recorded: the rule in Open Babel’s
ConnectTheDots(src/mol.cpp, read 2026-11-24:cutoff = SQUARE(rad[j] + rad[k] + 0.45)andif (d2 < 0.16)). The project took only the rule, with its own radii, and marks it provisional. - Why it matters: bonds perceived here feed formal-charge assignment (C5), the RDKit checks (C6), the force-field clean-up (C7) and hydrogen placement (C8), so a wrong bond gives a wrong chemistry report.
- Question: Is 0.45 Å a sound tolerance with these radii for organic molecules, including strained rings, hydrogen-bonded contacts and long bonds in the heavier main-group elements? Should the rule prune bonds that exceed an atom’s valence?
- Answer item C4 in a chemistry review issue
C5. Formal-charge assignment from bonds and total charge
Section titled “C5. Formal-charge assignment from bonds and total charge”- Now: an editor structure stores bonds and a total charge, and RDKit needs a charge on each atom. The rule assigns +1 to an N, P, O or S atom with one bond more than its lowest usual valence, and -1 to a B atom with four bonds. Any remaining structure charge goes, one unit at a time, to atoms with one bond fewer than their lowest usual valence: negative charges on O, then S, N and C, and positive charges on C. Valences are RDKit’s periodic-table valence lists. A structure the rule cannot explain is reported by the chemistry check (C6).
- Set in:
src/qchem_workbench/chem/rdmol.py:18-19and:45-76;docs/decisions.md:852. - Source recorded: no source recorded. The decision record calls the rule provisional “until the chemist collaborator reviews it”, and its examples are ammonium, hydronium, a nitro nitrogen, tetrafluoroborate, hydroxide, carboxylate, a nitro oxygen and a carbocation.
- Why it matters: the assigned charges decide which valences RDKit accepts, which force-field types the clean-up uses, and where
addhputs hydrogens. - Question: Does the rule give the right formal charges for the charged and zwitterionic organic species you expect researchers to draw (for example sulfoxides, phosphates, quaternary ammoniums, nitro groups and carbanions)? Which cases need a different rule?
- Answer item C5 in a chemistry review issue
C6. Chemistry checks shown after every edit
Section titled “C6. Chemistry checks shown after every edit”- Now: after every command the service reports, for each structure, RDKit’s
DetectChemistryProblemsfindings (such as an atom with more bonds than its valence allows), atoms with unpaired electrons that the multiplicity does not account for, and a structure charge that the atoms’ charges do not add up to. The editor shows these and never refuses an edit because of them, and it allows hypervalent atoms (a fragment attached to a saturated atom). - Set in:
src/qchem_workbench/chem/editing.py:131-165;docs/decisions.md:855and:842. - Source recorded: no source recorded beyond the use of RDKit’s own detector. The decision record marks the rules provisional until the chemist reviews them.
- Why it matters: this is the only guard against an invalid structure before a researcher submits a job, and the checks decide what the editor calls a problem.
- Question: Do these checks flag the problems that matter for organic molecules, and do they miss any common error (for example wrong aromaticity, impossible stereo, or an unrealistic charge separation)?
- Answer item C6 in a chemistry review issue
C7. Force-field clean-up: MMFF94 or UFF, 2000 steps
Section titled “C7. Force-field clean-up: MMFF94 or UFF, 2000 steps”- Now:
cleanminimises with MMFF94 when RDKit has parameters for every atom and with UFF otherwise, for at most 2000 steps, with any atoms the researcher names held fixed. It refuses a structure with more than 500 atoms (see C11). The structure-preparation path uses the same choice (C9), and its result status is not checked, because the quantum-chemical optimisation refines the geometry afterwards. - Set in:
src/qchem_workbench/chem/editing.py:14-17and:50-70;src/qchem_workbench/chem/smiles.py:23-29;src/qchem_workbench/chem/prepare.py:33and:108-111;docs/decisions.md:625and:853. - Source recorded: Halgren, J. Comput. Chem. 1996, 17, 490-519 (MMFF94); Rappe et al., J. Am. Chem. Soc. 1992, 114, 10024-10035 (UFF); and PyMOL’s
clean, which also uses MMFF94 (pymolwiki.org/index.php/Clean, read 2026-11-25). The step limit of 2000 has no source recorded. - Why it matters: the clean-up decides the starting geometry of every drawn molecule, and the optimiser may reach a different conformer from a different start.
- Question: Are MMFF94 with a UFF fallback and a 2000-step limit appropriate for preparing starting geometries of organic molecules, including charged species and heavier main-group elements? Should the workbench warn when it uses UFF?
- Answer item C7 in a chemistry review issue
C8. Hydrogen placement: addh and hydrogens missing from a file
Section titled “C8. Hydrogen placement: addh and hydrogens missing from a file”- Now:
addhlets RDKit fill each atom’s usual valence, given the formal charges from C5, and places the new hydrogens from the existing geometry (Chem.AddHs(mol, addCoords=True)). All new bonds are single bonds. When an imported file with 3D coordinates leaves hydrogens off some heavy atoms, the preparation step adds them the same way and warns the researcher to check the structure. - Set in:
src/qchem_workbench/chem/editing.py:72-96;src/qchem_workbench/chem/prepare.py:117-122;docs/decisions.md:854and:628. - Source recorded: no source recorded beyond RDKit’s behaviour. The decision record marks the rule provisional.
- Why it matters: the hydrogen positions seed the geometry of every molecule drawn heavy-atom-first, and a wrong valence assumption adds the wrong number of hydrogens.
- Question: Is RDKit’s default hydrogen placement acceptable as a starting geometry, and are there atom types (for example hypervalent sulfur or phosphorus, or charged centres) where the number of hydrogens it adds is wrong?
- Answer item C8 in a chemistry review issue
C9. 3D structure from a SMILES string or 2D sketch: ETKDGv3, fixed seed, one conformer
Section titled “C9. 3D structure from a SMILES string or 2D sketch: ETKDGv3, fixed seed, one conformer”- Now: a SMILES string, or a structure whose z coordinates are all below 1e-4 Å (treated as a flat sketch), is embedded in 3D with RDKit’s ETKDGv3 and the fixed random seed 20261123, so the same input always gives the same geometry. The workbench keeps one conformer, the first that embeds, and runs no conformer search. The force-field clean-up follows (C7). A structure with an odd electron count or any radical is refused. If the researcher states a charge that contradicts the formal charge in the input, the preparation refuses it.
- Set in:
src/qchem_workbench/chem/prepare.py:38-58,:73-78and:95-111;src/qchem_workbench/chem/smiles.py:8;docs/decisions.md:620-628. - Source recorded: Wang, Witek, Landrum and Riniker, J. Chem. Inf. Model. 2020, 60, 2044-2058 for ETKDGv3. The project records the seed, the single-conformer choice and the flatness threshold as “workbench choices, provisional” with no further source.
- Why it matters: for a flexible molecule the starting conformer decides which minimum the optimiser finds, and energy rankings of isomers depend on it. The preparation text says that ranking conformers needs a conformer search.
- Question: Is a single seeded ETKDGv3 conformer an acceptable starting geometry for the workbench’s four jobs? Should the workbench generate several conformers and optimise the lowest, or warn about flexible molecules (for example by counting rotatable bonds)?
- Answer item C9 in a chemistry review issue
C10. Size caps on chemistry operations: 500, 300, 3000 and 20,000 atoms
Section titled “C10. Size caps on chemistry operations: 500, 300, 3000 and 20,000 atoms”- Now:
cleanandaddhrefuse a structure of more than 500 atoms. The symmetry commands (pointgroup,symmetrize,replicate) refuse more than 300 atoms. The structure-preparation service accepts at most 300 atoms, hydrogens included. The service runs the chemistry checks of a scene within a budget of 3000 atoms per answer; a larger structure is checked only while it is the active one. The editor holds at most 20,000 atoms in a scene. - Set in:
src/qchem_workbench/chem/editing.py:23;src/qchem_workbench/chem/symmetry.py:47;src/qchem_workbench/chem/prepare.py:31;src/qchem_workbench/api/editor.py:84;src/qchem_workbench/editor/structure.py:19;docs/decisions.md:694-709,:856-857and:867. - Source recorded: workbench choices based on timings on the development machine (for example MMFF94 clean-up of water molecules took 0.55 s for 498 atoms, 2.24 s for 999 and 24.0 s for 2,100). They bound one request’s work and have no chemical basis.
- Why it matters: the caps decide which molecules the editor operations accept. The spec’s size target is about 50 atoms, so the caps are far above the intended use.
- Question: Do these caps cut off any structure size that your users will need for clean-up, hydrogens, symmetry or preparation (for example peptides, small proteins’ active sites or clusters)?
- Answer item C10 in a chemistry review issue
C11. symmetrize with a named group: the tolerance-widening policy
Section titled “C11. symmetrize with a named group: the tolerance-widening policy”- Now:
symmetrizewithout a group symmetrises to the group found within the tolerance. With a named group it tries the given tolerance (0.01 bohr when none is given), then doubles it, at most 30 times and up to 1 bohr, and stops at the first tolerance at which the structure has that group. It reports the tolerance and the largest atom displacement. A tolerance outside 1e-6 to 1 bohr is refused. - Set in:
src/qchem_workbench/chem/symmetry.py:37-42(limits) and:170-200(the policy);docs/decisions.md:863. - Source recorded: “this project’s own and provisional until the chemist collaborator reviews it; no program’s behaviour was copied”. The 1 bohr upper bound is a workbench choice, “about the length of the shortest bonds”.
- Why it matters: widening can move atoms by up to the final tolerance to force a requested symmetry onto a structure that does not have it, which silently changes a chemically meaningful geometry.
- Question: Is doubling the tolerance up to 1 bohr a sensible policy? Is 1 bohr too large a distortion to apply silently, and should the editor ask for confirmation above some displacement?
- Answer item C11 in a chemistry review issue
C12. Point-group naming and symmetry number in the editor
Section titled “C12. Point-group naming and symmetry number in the editor”- Now:
pointgroupnames the group from the operations the symmetry search finds, in PySCF’s spelling: two or more C3 axes give T, Td, Th, O, Oh, I or Ih; otherwise the principal axis of order n with n perpendicular C2 axes gives Dnh, Dnd or Dn by its mirror planes, and without them Cnh, Cnv, S2n or Cn; with no rotation the group is Cs, Ci or C1; linear structures are D∞h or C∞v. The symmetry number σ is the number of proper rotations. The classifier compares axes and planes with a tolerance of 1e-4. The runner’s thermochemistry uses the same search at the same default tolerance, so both report the same group. - Set in:
src/qchem_workbench/chem/symmetry.py:90-136(_classify);src/qchem_workbench/runner/symmetry.py:210-217;docs/decisions.md:861and:867. - Source recorded: the group definitions are described as standard, and the project checks the classifier against PySCF’s names inside the engine container (
tests/engine/test_editor_point_groups.py). The decision record marks the classifier and the PySCF spelling provisional until the chemist reviews them. - Why it matters: the reported group and σ feed the thermochemistry correction RT ln σ.
- Question: Is the classification rule complete and correct for the molecules you expect (does it handle, for example, D2d versus D2h, S4 and the icosahedral groups correctly), and is the number of proper rotations the σ you want in the editor?
- Answer item C12 in a chemistry review issue
C13. replicate: the orientation of each point group
Section titled “C13. replicate: the orientation of each point group”- Now:
replicate <group>, <atoms>applies the group’s operations about the origin to atoms the researcher placed. The principal axis lies along z; a C2 axis of a D group lies along x; the vertical mirror of a Cnv group contains x; the cubic groups have their C2 axes along x, y and z (Td also takes a mirror through the plane perpendicular to (1, -1, 0)); the icosahedral groups put a C5 axis along z and a C2 axis along (0, 1, 1.618034). Group names are matched without regard to case, and rotation orders above 240, groups with more than 240 operations and builds of more than 200,000 bonds are refused. - Set in:
src/qchem_workbench/chem/symmetry.py:228-262(generators) and:220-225(limits);docs/decisions.md:865. - Source recorded: the conventions “follow the orientations that group-theory textbooks use for the Schoenflies groups (for example Cotton, Chemical Applications of Group Theory, 3rd edition, Wiley, 1990)”. The record says this was “not re-read for this project, so the chemist is to confirm them”. The citation therefore comes from memory and has not been checked.
- Why it matters: the orientation decides where the images of a researcher’s atoms are placed, so a different convention gives a different structure for the same input.
- Question: Please check the orientation of each group against Cotton or another standard reference you trust (in particular the placement of the C2 and σv axes in D, Dnd, Cnv and the cubic and icosahedral groups), and tell us if a different convention is standard.
- Answer item C13 in a chemistry review issue
C14. replicate: merge threshold for coincident images
Section titled “C14. replicate: merge threshold for coincident images”- Now: an image within 0.001 Å of an atom of the same element is not added, and a bond of a replicated atom is copied to its images when the atom at its other end has an image too (for example an atom on the axis).
- Set in:
src/qchem_workbench/chem/symmetry.py:35(_MERGE_ANGSTROM) and:300-360;docs/decisions.md:865. - Source recorded: “0.001 Å is a workbench choice, far below any bond length and above the rounding of a file written with four decimals”. No other source is recorded.
- Why it matters: too large a value merges real neighbouring atoms, and too small a value leaves duplicate atoms where an image coincides with an existing atom.
- Question: Is 0.001 Å a suitable merge distance for atoms a researcher places on or near a symmetry element?
- Answer item C14 in a chemistry review issue
D. Spectra and thermochemistry
Section titled “D. Spectra and thermochemistry”D1. Thermochemistry conditions: 298.15 K and 101325 Pa
Section titled “D1. Thermochemistry conditions: 298.15 K and 101325 Pa”- Now: the workbench computes thermochemistry at 298.15 K and 101325 Pa (1 atm) unless the job input sets
temperature_korpressure_pa. The gas-phase ideal-gas standard state applies, and the interface and exports state the conditions beside each value. - Set in:
src/qchem_workbench/core/defaults.py:38-39;src/qchem_workbench/runner/frequencies.py:233-238. - Source recorded: the temperature as “IUPAC standard ambient temperature”, and the pressure as “PySCF 2.15.1 default (
hessian.thermo.thermopressure, 1 atm)”. The writer of this packet notes that IUPAC’s standard ambient temperature and pressure convention pairs 298.15 K with 1 bar (100000 Pa); the project has not recorded that note or a decision about it. - Why it matters: the pressure changes the translational entropy and so the Gibbs energy (the 1 atm and 1 bar standard states differ by RT ln 1.01325, about 0.008 kcal/mol in G at 298.15 K), and published values that use a different standard state need a conversion.
- Question: Should the default standard-state pressure be 1 atm or 1 bar? Should the workbench add a concentration-standard-state correction (for example 1 mol/L) for comparison with solution-phase work?
- Answer item D1 in a chemistry review issue
D2. Thermochemistry treatment: RRHO with no low-frequency or quasi-harmonic correction
Section titled “D2. Thermochemistry treatment: RRHO with no low-frequency or quasi-harmonic correction”- Now: the workbench passes the harmonic frequencies to PySCF’s
thermo.thermoand reports the zero-point energy, enthalpy, entropy and Gibbs energy from the rigid-rotor harmonic-oscillator (RRHO) model, with the symmetry number from B6. It adds no low-frequency correction and no quasi-harmonic or free-rotor treatment of its own, and it applies no scale factor to the frequencies that enter the zero-point energy and thermal terms. It computes thermochemistry only for a minimum (see B5). - Set in:
src/qchem_workbench/runner/frequencies.py:221-251;docs/spec.md:214and:303. - Source recorded: no source recorded for the absence of a low-frequency or quasi-harmonic treatment, and none for using unscaled frequencies in the thermal terms. The project records only that RRHO assumes a stationary minimum.
- Why it matters: low-frequency torsions and soft modes dominate the entropy error of flexible molecules, so the Gibbs energies and relative free energies of conformers and isomers depend on this choice.
- Question: Should the workbench apply a quasi-harmonic or low-frequency correction by default (and which, with which cut-off), or leave pure RRHO with a documented limit? Should the zero-point energy and thermal terms use scaled frequencies?
- Answer item D2 in a chemistry review issue
D3. IR frequency scale factor: default 1 (unscaled)
Section titled “D3. IR frequency scale factor: default 1 (unscaled)”- Now: the interface applies a scale factor of 1 to the predicted frequencies by default and states “unscaled” on the plot and in exports. The researcher can type a published factor, and the export records which factor was used. The spec intends to show the workbench’s own fitted factor for each method beside the published ones once validation tier C has run.
- Set in:
web/app/src/chem/spectrum.ts:3-14(DEFAULT_SCALE_FACTOR);web/app/src/results/SpectrumView.tsx:72-77;docs/spec.md:216. - Source recorded: “Workbench display choice, provisional until the chemist collaborator’s review; the fitted scale factor of each method comes from validation tier C”. No factor is stored in the app yet. The spec’s chemistry defaults table lists the fitted factor as the default, whereas the interface currently defaults to 1, so the two differ until tier C runs.
- Why it matters: harmonic frequencies from these methods run several per cent above experiment, so an unscaled spectrum compared with a measured one misleads a researcher on peak positions.
- Question: Should the interface default to a published factor for each method (see E3) until the workbench’s own factors exist, and which factors, with what warning about the method and basis they apply to?
- Answer item D3 in a chemistry review issue
D4. Spectrum line shape and the measured-peak matching rule
Section titled “D4. Spectrum line shape and the measured-peak matching rule”- Now: the predicted spectrum broadens each mode with a Lorentzian of 10 cm⁻¹ full width at half maximum, with peak heights equal to the computed intensities. To compare with measured peaks, the interface pairs each measured peak with the nearest scaled real mode whose intensity is at least 1 km/mol, and treats the pairing as a reading aid that makes no assignment.
- Set in:
web/app/src/chem/spectrum.ts:7-11(DEFAULT_FWHM_CM1),:38-55(broadening) and:91-107(matchPeaks). - Source recorded: “Workbench display choice, provisional until the chemist collaborator’s review”. No source is recorded for the 10 cm⁻¹ width or the 1 km/mol cut-off.
- Why it matters: the line shape and the cut-off decide how a predicted spectrum looks next to an experimental one, and which modes a researcher sees as matched.
- Question: Are a Lorentzian of 10 cm⁻¹ FWHM and a 1 km/mol matching cut-off sensible defaults for comparing a computed gas-phase spectrum with a measured IR spectrum? Should the line shape be Gaussian, or the width differ for condensed-phase work?
- Answer item D4 in a chemistry review issue
D5. IR intensities: method and the integration-grid limit
Section titled “D5. IR intensities: method and the integration-grid limit”- Now: IR intensities come from the analytic Hessian’s orbital response and the dipole derivatives, on both the CPU and the GPU. Both omit the response of the integration grid to nuclear motion. For r2SCAN-3c on water, the analytic atomic polar tensors differ from finite differences by up to 2.2e-3 au at level 3, 8.6e-4 au at level 5 and 2.8e-4 au at level 7, and they match finite differences on a frozen grid to 7e-6 au. At level 5 the water intensities are 77.261, 4.161 and 54.808 km/mol analytically against 77.232, 4.157 and 54.792 km/mol from differences. The workbench computes intensities from its own dipole derivatives, because GPU4PySCF 1.9.2 assigns ECP-reduced charges as mass indices (oxygen receives carbon’s mass in vDZP), which gives wrong frequencies and intensities for any molecule with an ECP; the project reported the fault upstream.
- Set in:
src/qchem_workbench/runner/frequencies.py:21-137and:140-153;docs/decisions.md:188-223;docs/spec.md:348. - Source recorded: the project’s own measurements on the water fixture (
docs/decisions.md:190-215) and PySCF’s meta-GGA grid warning. The tests assert bounds (1.2e-3 au for r2SCAN-3c at level 5, 1e-4 au for ωB97X-3c on the GPU at level 3). No chemist has judged whether these accuracies are sufficient for assigning experimental spectra. The project measured only water and a few small cases. - Why it matters: researchers use relative intensities to identify functional groups, so an intensity error of a few per cent could change an assignment.
- Question: Are the measured intensity deviations acceptable for the workbench’s use (checking a structure by IR), and do you want a larger molecule or a stricter reference before the project trusts them?
- Answer item D5 in a chemistry review issue
D6. Dipole moments are reported about the centre of mass
Section titled “D6. Dipole moments are reported about the centre of mass”- Now: the dipole moment is computed in debye about the centre of mass, using PySCF’s average atomic masses, and the result records
dipole_origin = "centre_of_mass". A neutral molecule’s dipole does not depend on the origin; an ion’s does. - Set in:
src/qchem_workbench/runner/engine.py:134-148;docs/decisions.md:290-292. - Source recorded: decided by the project lead on 2026-11-23 as “the usual reference point for reporting”. The decision is not labelled provisional and no literature source is recorded.
- Why it matters: for charged species the reported dipole changes with the origin, and a comparison with literature values needs the same origin.
- Question: Is the centre of mass the right origin for ions, or should the workbench report the dipole about the centre of charge, or not report a dipole for ions?
- Answer item D6 in a chemistry review issue
D7. Relative energies of isomers and conformers
Section titled “D7. Relative energies of isomers and conformers”- Now: the isomer table ranks structures by electronic energy ΔE and, for minima, by Gibbs energy ΔG, in kJ/mol. It compares energies only within one method and basis set, only for the same molecular formula, and compares Gibbs energies only at the same temperature and pressure. It applies no zero-point correction to ΔE and no Boltzmann weighting of conformers.
- Set in:
web/app/src/chem/isomers.ts:43-82;docs/spec.md:24. - Source recorded: no source recorded for these conventions.
- Why it matters: researchers use this table to decide which isomer or tautomer is most stable, and the choices above can change the order of close pairs.
- Question: Should the table also show a zero-point-corrected energy, and should it offer Boltzmann-weighted populations for conformers? Are the comparison rules (same formula, same level, same conditions) the right ones?
- Answer item D7 in a chemistry review issue
E. Reference data and validation settings
Section titled “E. Reference data and validation settings”These items describe the validation suite in src/qchem_workbench/validation, which Plan 6 specified. The suite’s reference extracts are in src/qchem_workbench/validation/data. The project has run the smoke profile but not yet a full run, so no item here quotes a validation result.
E1. Shimanouchi gas-phase fundamentals (the transcribed values)
Section titled “E1. Shimanouchi gas-phase fundamentals (the transcribed values)”- Now: the suite holds a transcription of selected gas-phase vibrational fundamentals for 22 small molecules, from water to cyclopropane (198 fundamentals, of which 158 enter the scale-factor fit). Examples: water 3657, 1595 and 3756 cm⁻¹; ammonia 3337, 950, 3444 (doubly degenerate) and 1627 (doubly degenerate) cm⁻¹; carbon dioxide 1333, 667 (doubly degenerate) and 2349 cm⁻¹.
- Set in:
src/qchem_workbench/validation/data/shimanouchi_fundamentals.toml. - Source recorded: T. Shimanouchi, Tables of Molecular Vibrational Frequencies, Consolidated Volume I, NSRDS-NBS 39 (National Bureau of Standards, 1972). The values were transcribed by eye on 2026-11-24. On the same date the project checked every row against the rendered page images and found no differences, and a script (
check-shimanouchi) found every value in the text layer of its PDF page (docs/decisions.md, validation data sources). No chemist has checked the transcription. - Why it matters: these values are the experimental reference for the fitted scale factors and the tier C error statistics.
- Question: Please spot-check the transcribed values for the molecules you know best against the printed tables, and tell us if any value or degeneracy is wrong.
- Answer item E1 in a chemistry review issue
E2. Which fundamentals enter the fit, and how modes are paired
Section titled “E2. Which fundamentals enter the fit, and how modes are paired”- Now: the fit uses only fundamentals with accuracy grades A to C (an uncertainty of 6 cm⁻¹ or less), a gas-phase value, and no comment code OC, CF or SF (estimated from an overtone or combination, calculated, or from the solid or another state). Computed and experimental modes are paired by frequency order, counting degeneracy, and the report lists every pair in its per-mode tables, so a reader can find a pair that may be wrongly ordered.
- Set in:
src/qchem_workbench/validation/shimanouchi.py:19-20(the included grades and excluded comment codes) and:165(pairing by order); the grade bands (A: 0-1, B: 1-3, C: 3-6, D: 6-15, E: 15-30 cm⁻¹) are recorded in the header ofsrc/qchem_workbench/validation/data/shimanouchi_fundamentals.toml. - Source recorded: “Shimanouchi section 3.6 defines the grades; the comments mark values that were not observed directly”. The inclusion rule is recorded as “a workbench choice, provisional until the chemist collaborator reviews it”. The result has no mode symmetry labels, so pairing by order is a documented limit.
- Why it matters: a wrongly paired or poorly measured mode distorts the fitted factor.
- Question: Is the grade A to C cut-off sound, and should modes with Fermi resonance (FR) or overlapped bands (OV) be excluded or kept? Is pairing by frequency order acceptable for these small molecules, or do you want symmetry-labelled pairing?
- Answer item E2 in a chemistry review issue
E3. Published frequency scale factors shown beside the workbench’s own
Section titled “E3. Published frequency scale factors shown beside the workbench’s own”- Now: the validation report shows these published factors, with the method labelled as the source labels it: r2SCAN-3c 0.9688 (relative 0.982); B3LYP with D3(BJ) in def2-TZVP 0.9671 (relative 0.979); PBE0 with D3(BJ) in def2-TZVP 0.9591 (relative 0.967); and B3LYP/def2-TZVP without dispersion 0.959. The project found no published factor for ωB97X-3c, ωB97X-V/def2-TZVP or HF/def2-TZVP, and the report says so.
- Set in:
src/qchem_workbench/validation/data/published_scale_factors.toml. - Source recorded: D. S. Tikhonov et al., ChemPhysChem 2024, 25, e202400547, Table 1 (fundamentals, fitted against CCCBDB experimental values), and the Truhlar group’s Database of Frequency Scale Factors, Version 5 (Kanchanakungwankul et al., 2021). Both were read on 2026-11-24, and the decision record notes that values extracted from the PDF “need checking by eye” (
docs/decisions.md). No chemist has checked the numbers. - Why it matters: researchers will multiply computed frequencies by these factors to compare with experiment.
- Question: Please check each factor against its source table and confirm that the method and basis label matches what the workbench computes (for example whether a factor for “D3BJ” refers to the same dispersion model as the workbench’s). Are any of these factors unsuitable to recommend?
- Answer item E3 in a chemistry review issue
E4. How the workbench fits its own scale factor
Section titled “E4. How the workbench fits its own scale factor”- Now: the fit uses a least-squares factor s = Σων / Σω² over the fundamentals from E2, and a relative factor that minimises the squared relative error (Tikhonov et al. 2024, equation 5). Each distinct fundamental counts once, and only minima enter the fit. The start geometries are CCCBDB’s experimental Cartesian coordinates, or the SMILES embedding for methylamine and acetaldehyde, which have none.
- Set in:
src/qchem_workbench/validation/stats.py:55(fit_scale_factor) andsrc/qchem_workbench/validation/tier_c.py:90(the start geometries). - Source recorded: Scott and Radom, J. Phys. Chem. 1996, 100, 16502 and Tikhonov et al., ChemPhysChem 2024, 25, e202400547. The report marks every fitted factor provisional until the chemist reviews it.
- Why it matters: the fitted factor becomes the workbench’s recommended factor for each method.
- Question: Is this the right way to derive a scale factor (including the choice to fit fundamentals only and to start from experimental geometries), and is a fit over 22 small molecules enough to publish a factor for each method?
- Answer item E4 in a chemistry review issue
E5. CCCBDB structure and dipole conventions
Section titled “E5. CCCBDB structure and dipole conventions”- Now: a CCCBDB geometry whose comment says
reorequilibriumcounts as an equilibrium structure;r0,rz,rgandracount as vibrationally averaged;rsandrmare listed separately; any other comment counts as not stated. For dipole moments the suite uses the first configuration of the ground state and lists nonpolar molecules but leaves them out of the statistics, because a zero by symmetry says nothing about method error. - Set in:
src/qchem_workbench/validation/cccbdb.py:113-144(parse_properties_pageandstructure_type) andsrc/qchem_workbench/validation/tier_c.py:173(the nonpolar molecules). - Source recorded: the spec asks for the equilibrium-versus-averaged distinction (
docs/spec.md:255), and CCCBDB states it in a comment column. The mapping of comment codes to categories is a workbench choice with no further source. - Why it matters: comparing a computed equilibrium geometry with a vibrationally averaged experimental one inflates the apparent error.
- Question: Is this classification of CCCBDB structure types right, and is the “first configuration of the ground state” the correct experimental dipole to compare with?
- Answer item E5 in a chemistry review issue
E6. Validation tolerances
Section titled “E6. Validation tolerances”- Now: tier A0 requires CPU and GPU to agree to 1e-6 hartree in energy, 1e-5 hartree/bohr in gradient and 0.5 cm⁻¹ in frequency; Hartree-Fock energies to match Psi4 reference values to 1e-6 hartree after the nuclear repulsion matches to 1e-8 hartree; DFT energies to match Psi4 to 5e-5 hartree. Tier A1 requires per-reaction agreement with published GMTKN55 results to 0.10 kcal/mol and each subset’s mean absolute deviation to within 0.02 kcal/mol. Tier B has no pass or fail threshold. The engine tests that decide whether a method runs on the GPU use their own bounds (0.5 cm⁻¹ and 0.5 km/mol, and 1e-6 hartree/bohr in the residual gradient).
- Set in:
docs/spec.md:252-255;src/qchem_workbench/validation/tier_a0.py:25-32(TOLERANCES) andsrc/qchem_workbench/validation/tier_gmtkn.py:41-42;docs/decisions.md. - Source recorded: the DFT tolerance is “based on GPU4PySCF’s own published comparison with Psi4” (differences of 1e-7 to 2.2e-5 hartree). The spec marks all of them “provisional until a pilot run and a chemist’s review”.
- Why it matters: the tolerances decide what counts as agreement with a reference, and so what the project may claim about its results.
- Question: Are these tolerances appropriate for judging cross-engine agreement and for reproducing published DFT relative energies, and are the A1 limits too tight or too loose?
- Answer item E6 in a chemistry review issue
E7. Choice of reference sets and functionals for tiers A1 and B
Section titled “E7. Choice of reference sets and functionals for tiers A1 and B”- Now: tier A1 uses r2SCAN-3c on six GMTKN55 subsets (ISO34, TAUT15, ACONF, SCONF, BUT14DIOL and Amino20x4) and PBE0-D3(BJ)/def2-QZVP on ACONF, compared with the published results pages, using each results page’s own reference value. Tier B reports every offered method’s deviation on those subsets (about 225 reactions) with the def2-TZVP default for the non-composite methods. The workstation profile leaves Amino20x4 out for the four def2-TZVP methods and runs PBE0-D3(BJ)/def2-QZVP on ACONF only, and the full profile runs both on every subset. The A0 set is ten small molecules and the Psi4 HF and DFT test cases listed in
data/a0.toml. - Set in:
src/qchem_workbench/validation/profiles.py:13-90,src/qchem_workbench/validation/data/a0.tomlanddocs/spec.md:253-254. - Source recorded: GMTKN55 (Goerigk et al., Phys. Chem. Chem. Phys. 2017, 19, 32184) and the Psi4 test suite; the plan notes that the ACONF r2SCAN-3c results page lists references up to 0.205 kcal/mol from ACONF’s own
.resfile. The selection is a workbench choice, provisional until the chemist reviews it. - Why it matters: the subsets decide what the project can say about relative-energy accuracy for isomers, tautomers and conformers.
- Question: Are these subsets the right ones for the workbench’s isomer-ranking job, and is anything important missing (for example barrier-free reaction energies, noncovalent interactions or halogen-containing molecules)?
- Answer item E7 in a chemistry review issue
E8. Energy unit conversions (CODATA edition)
Section titled “E8. Energy unit conversions (CODATA edition)”- Now: the interface converts hartree to kJ/mol with 2625.499639479 and to eV with 27.211386245981, which are CODATA 2022 values, and to kcal/mol with the exact thermochemical calorie of 4.184 J. The validation suite uses the same CODATA 2022 values, from
core/units.py, and a test compares that file withunits.ts. Plan 6 had proposed the CODATA 2018 value, 627.5094740630558 kcal/mol per hartree. - Set in:
web/app/src/chem/units.ts:4-10;src/qchem_workbench/core/units.py:13-14. - Source recorded: CODATA 2022 (NIST) for both the interface and the validation suite. The difference from CODATA 2018 is far below any chemical significance.
- Why it matters: the difference does not change a chemical conclusion. It matters only so that the app and the validation report use one stated edition.
- Question: Which CODATA edition and which calorie (thermochemical 4.184 J) should the project standardise on?
- Answer item E8 in a chemistry review issue
An open-source project on GitHub. Built by Graham Morley.